1
1

Product sort

1/1
Number of views:
1000

ADSS-All dry-Flat FRP-200M 12core 24core and 72core

Number of views:
1000
Product serial number
Quantity
-
+
Product description

ADSS-All dry-Flat FRP-200M 12core 24core and 72core

  1. Cable cross-section (only for reference, not to scale)

  1. Cable description

Loose tube construction, tubes with water blocking yarn filled, elements (tubes and fillers when necessary) laid up around non-metallic central

strength member(SZ), polyester yarns used to bind the cable core, water blocking tape, aramid yarns, 1 ripcord, HDPE inner sheath,

flat FRP armored for Anti-rodent, water blocking tape wrapped, 1 ripcord and HDPE outer sheath.

Useful life30 years

  1. Fiber & tube color

Fiber color code

No.

1

2

3

4

5

6

Color

Blue

Orange

Green

Brown

Gray

White

No.

7

8

9

10

11

12

Color

Red

Black

Yellow

Violet

Pink

Aqua

Loose tube color code

No.

1

2

3

4

5

6

Color

Blue

Orange

Green

Brown

Gray

White

  1. Structure parameter

Item

Contents

Unit

Value

Fiber count

Number

/

12

24

72

Cable structure

/

/

1+6

Fiber No. per tube

Number

/

12

Loose tube

Material

/

PBT

 

Item

Contents

Unit

Value

 

Number

/

1

2

6

Central strength member

Material

/

FRP

 

Outer sheath

Thickness

mm

Nominal 1.7

Material

/

HDPE

Ripcord

Material

/

Kevlar

Cable diameter

±5%

mm

14.0

Cable weight

±10%

kg/km

156

156

159

Weather condition

/

/

NESC Light

Max. span

/

m

200

Installation sag

/

%

≥1.5

Max. tensile load

MAT

N

3400

Note: Sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values.

  1. Mechanical & Environmental Performance

Item

Contents

Value

Max. crush resistance

Short term

3000 N/100mm

 

Min. bending radius

Installation

25 x cable diameter

Operation

15 x cable diameter

 

Temperature range

Operation

-30~ +70

Installation

-10~ +60

Storage/transportation

-30~ +70

  1. Main mechanical & environmental performance test

Item

Test Method

Acceptance Condition

Tensile Strength

IEC 60794-1-21-E1

  • Load: MAT
  • Length of cable: ≥ 50m
  • Load time: 1min
  • Fiber strain £ 0.33%
  • Loss change £ 0.1dB@1550nm after test.
  • No fiber break and no sheath damage.

Crush Test

IEC 60794-1-21-E3

  • Load: Short term crush
  • Load time: 1min
  • Loss change £ 0.1dB@1550nm after test.
  • No fiber break and no sheath damage.

Impact Test

IEC 60794-1-21-E4

  • Points of impact: 3
  • Times of per point: 1
  • Impact energy: 4.5J
  • Loss change £ 0.1dB@1550nm after test.
  • No fiber break and no sheath damage.

Repeated Bending

IEC 60794-1-21-E6

  • Bending radius: 25 x OD
  • No. of cycle: 25
  • Loss change £ 0.1dB@1550nm after test.
  • No fiber break and no sheath damage.

 

Torsion

IEC 60794-1-21-E7

  • Length: 2m
  • Twist angle: ±180°
  • No. of cycle: 10
  • Loss change £ 0.1dB@1550nm after test.
  • No fiber break and no sheath damage.

Water Penetration

IEC 60794-1-22-F5B

  • Height of water: 1m
  • Sample length: 3m
  • Time: 24h

- No water leak from the cable core of the opposite end. (exclude the FRP layer )

 

Item

Test Method

Acceptance Condition

 

Temperature Cycling IEC 60794-1-22-F1

  • Temperature: -30~+70
  • Time of each step: 12h
  • Number of cycle: 2
  • Loss change £ 0.15dB/km @1550nm.
  • No fiber break and no sheath damage.
  1. OPTICAL FIBER

G657A2 Characteristic of Optical Fiber

 

Item

 

Unit

Specification

G. 657A2

 

Mode field diameter

1310nm

mm

8.6 ± 0.4

1550nm

mm

9.6 ± 0.5

Cladding diameter

mm

125.0 ± 0.7

Cladding non-circularity

%

£1.0

Core concentricity error

mm

£0.5

Coating diameter

mm

245 ± 10

Coating/cladding concentricity error

mm

£12

Cable cut-off wavelength

nm

£ 1260

 

Attenuation Coefficient

1310nm

dB/km

£0.4

1550nm

dB/km

£0.28

 

Macro-bend loss (1 turn,7.5mm radius)

1550nm

dB

£0.5

1625nm

dB

£1.0

 

Macro-bend loss (1 turn,10mm radius)

1550nm

dB

£0.1

1625nm

dB

£0.2

 

Macro-bend loss (10 turns,15mm radius)

1550nm

dB

£0.03

1625nm

dB

£0.1

Coating material

/

acrylate

Proof stress level

kpsi

≥100

Other parameters meet standard ITU-T G.657A2.

 

wooden drum can be made according to the clients' specifications.

We could not find any corresponding parameters, please add them to the properties table

Inquiry now

Username used for comment:
客户留言
Description:
验证码

FEEDBACK

留言应用名称:
客户留言
描述:
验证码

CONTACT

Tel:

Fax:

Mobile:

Email:

Skype ID:

Whatsapp:

Wechat: 

Add:

0086-756-2255950

0086-756-2255926

0086-13926923676

sales@zhsurelink.com

pingshengwang1

+8613926923676

surelink2008

No.4, Xing Guo Street, Nan Keng Industrial Zone, Xiangzhou district, Zhuhai, China

Search
Search
Cancel

Copyright: Zhuhai Surelink Communication Cable Co.,Ltd.    粤ICP备2021097875号   Powered by www.300.cn  SEOLabel