18awg wire drop wire outdoor drop wire aerial drop wire copper or copper clad steel CCS PE jacket 2 Core Drop Wire telephone copper wire outdoor drop wire telephone cable
18awg wire drop wire outdoor drop wire aerial drop wire copper or copper clad steel CCS PE jacket 2 Core Drop Wire telephone copper wire outdoor drop wire telephone cable
1. CONDUCTORS
Material: 18 AWG Electrolytic, minimum 99,90% pure copper (Cu), considering the Silver (Ag) as copper for the calculation of this percentage
Density: 8.89 g/cm³ at 20ºC
Dimensions: Nominal Diameter: 1.024 mm (18AWG)
Specific Section: 0.824 mm squre
Min. Diameter : 1.014 mm
Max. Diameter: 1.034 mm
2. Conductor traction resistance: Minimum 45.8 kg/mm squre
Minimum elongation of a conductor at 1500 mm: 0.86%
Electrical properties at 20ºC:
Resistivity: Max. 0.01793 Ohm mm²/m
Density/Resistivity: Max. 0.15940 g/m²
DC Resistance at 20ºC: Max. 44.5 Ohms/km-Pair
3. INSULATION
Type: PVC 75ºC
Flame resistance: According to .VW-1 (Vertical Wire) Flame Test
Maximum Temperature: 75ºC
Physical requirements:
a) Before Aging:
- Breaking Strength: Minimum 13.8 MPa (1.41 kg/mm²)
- Elongation until Breaking: Minimum 150%
b) Aging in a Hot Air Chamber at 121ºC ± 1ºC during 168 hrs:
- Breaking Strength (percentage of the value without aging): Maximum 120
Minimum 80
- Elongation until Breaking (minimum percentage of the value without aging): 75
c) Aging by immersion in oil at 70ºC ± 1ºC during 4 hrs:
- Minimum Breaking Strength (percentage of the value without aging): 85
- Elongation until Breaking (minimum percentage of the value without aging): 85
4. Nominal dimensions and tolerances:
A = Height : 3.5mm ± 0.2 mm
B = Width : 7.0mm ± 0.4 mm
C = Distance between conductors : 3.5mm ± 0.4mm
D = Thickness of the nerve : 1.3mm ± 0.3 mm
Insulation thickness: Nominal: 1.24mm
Minimum at any point: 0.9mm
Polarity identification: Red trace of 0.8mm + 0.4 mm – 0.1mm, extruded longitudinally over one of the conductors of the drop wire
Approximate weight: 39 kg/km
Electrical requirements and tests:
Sparkling: Voltage application during the manufacturing process (after the extrusion) in order to detect pores or other insulation failures
Minimum insulation resistance at 15.6 ºC:
- Between conductors: 92 Mohm/km (500 VCC power must be applied during 1 minute. This test must be realized dry. )
Minimum dielectric breakdown strength at VCC:
- between both conductors: The insulation must resist during 3 minutes a continuous voltage of 7500 VCC. This test must be realized dry)
Mutual capacity: 64 - 79 nF/km at 1 KHz
Characteristic impedance: 124 ± 20 Ohms
Attenuation: (must be measured in at least 5 samples):
Maximum Individual | Maximum Average | |
1 KHz | 1.3 dB/km | 0.95 dB/km |
150 KHz | 5.2 dB/km | 4.70 dB/km |
772KHz | 18.0 dB/KM | 15.00 dB/km |